Procédure pour réparer les services d'une installation de SolarWinds.
How to Replace Job Engine
- Stop all Orion services from Orion Service Manager.
- Go to C:\Documents and Settings\All Users\Application Data\SolarWinds\JobEngineV2\Data\JobEngine35.sdf file and rename it to JobEngine35_OLD.sdf
- Then create a copy of C:\Documents and Settings\All Users\Application Data\SolarWinds\JobEngineV2\Data\JobEngine35 - Blank.sdf one and rename it to JobEngine35.sdf.
- This way you have the old one to revert back to and you always have a blank copy in case issue reoccurs.
- Right click on properties of the JobEngine35.sdf you have created and untick the read only box and click ok.
How to Replace Job Tracker
- Stop all Orion services from Orion Service Manager.
- Go to C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\JobTracker.sdf file and rename it to JobTracker_OLD.sdf
- Then create a copy of C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\JobTracker - Blank.sdf one and rename it to JobTracker.sdf.
- This way you have the old one to revert back to and you always have a blank copy in case issue reoccurs.
- Right click on properties of the JobTracker.sdf you have created and untick the read only box and click ok.
How to Replace Polling Collector
- Stop all Orion services from Orion Service Manager.
- Go to C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\PollingController.sdf file and rename it to PollingController_OLD.sdf
- Then create a copy of C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\PollingController - Blank.sdf one and rename it to PollingController.sdf.
- This way you have the old one to revert back to and you always have a blank copy in case issue reoccurs.
- Right click on properties of the PollingController.sdf you have created and untick the read only box and click ok.
- Restart all Orion Services
How to Repair Job Engine
- Open C:\Documents and Settings\All Users\Application Data\SolarWinds\Installers.
- On a 2008 system, this will be under C:\ProgramData\Solarwinds\Installers.
- Run the Jobengine.msi and select Repair.
How to Repair Job Engine V2
- Open C:\Documents and Settings\All Users\Application Data\SolarWinds\Installers.
- On a 2008 system, this will be under C:\ProgramData\Solarwinds\Installers.
- Run the Jobengine.v2.msi and select Repair.
How to Repair Information Service
- Open C:\Documents and Settings\All Users\Application Data\SolarWinds\Installers.
- On a 2008 system, this will be under C:\ProgramData\Solarwinds\Installers.
- Run the InformationService.msi and select Repair.
How to Repair Collector Service
- Open C:\Documents and Settings\All Users\Application Data\SolarWinds\Installers.
- On a 2008 system, this will be under C:\ProgramData\Solarwinds\Installers.
- Run the CollectorInstaller.msi and select Repair.